GUIDES / Specification

What is a normal temperature for server memory?

The short answer is below; expand for the reasoning and the boundary conditions.

Under normal load, DDR5 RDIMM device temperatures run at 40–60°C and can reach 70–80°C at full load. JEDEC sets the DRAM junction limit at 95°C; platforms usually raise fan speed near 85°C, and sustained operation above 85°C triggers throttling.

Which temperature to read

An RDIMM carries two temperature sensors, one at each end of the module, and the SPD Hub reports them to the BMC.

The BMC reads sensor temperature, which is typically 5–10°C below junction temperature. To judge whether a module is overheating, look at junction temperature or the platform fan-curve thresholds.

How to keep it cool

Servers rely on chassis airflow, not heat spreaders. Keep intake air below 25°C and airflow over the memory area above 1 m/s, and overheating is unlikely.

For high-density configurations (16 modules or more), add memory air ducts. If the airflow design is poor, reduce speed before adding fans.

RangeStatusAction
40–60°CNormal loadNone
60–80°CFull loadCheck airflow and intake temperature
80–85°CHighRaise fan curve, check air ducts
> 85°CAt riskThrottle or improve cooling

FAQ

Related questions

Does a module without a heat spreader overheat more easily?

Server RDIMMs rely on chassis airflow and are commonly shipped without heat spreaders. As long as airflow and intake temperature are within spec, device temperature stays under control.

Check the module in your hand

Enter the 12-character serial number from the label to see model, batch and warranty status.

Check serial